| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| This vulnerability exists in Meon KYC solutions due to missing restrictions on the number of incorrect One-Time Password (OTP) attempts through certain API endpoints of login process. A remote attacker could exploit this vulnerability by performing a brute force attack on OTP, which could lead to gain unauthorized access to other user accounts. |
| The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access. |
| On Mercku M6a devices through 2.1.0, session tokens remain valid for at least months in some cases. |
| The affected product allows unauthenticated access to Real Time Streaming Protocol (RTSP) services, which may allow an attacker unauthorized access to camera configuration information. |
| Nautobot Single Source of Truth (SSoT) is an app for Nautobot. Prior to version 3.10.0, an unauthenticated attacker could access this page to view the Service Now public instance name e.g. companyname.service-now.com. This is considered low-value information. This does not expose the Secret, the Secret Name, or the Secret Value for the Username/Password for Service-Now.com. An unauthenticated member would not be able to change the instance name, nor set a Secret. There is not a way to gain access to other pages Nautobot through the unauthenticated Configuration page. This issue has been patched in version 3.10.0. |
| Karapace is an open-source implementation of Kafka REST and Schema Registry. Versions 5.0.0 and 5.0.1 contain an authentication bypass vulnerability when configured to use OAuth 2.0 Bearer Token authentication. If a request is sent without an Authorization header, the token validation logic is skipped entirely, allowing an unauthenticated user to read and write to Schema Registry endpoints that should otherwise be protected. This effectively renders the OAuth authentication mechanism ineffective. This issue is fixed in version 5.0.2. |
| General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which
could allow an attacker to send GET requests to obtain sensitive device
information. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system. |
| Burk Technology ARC Solo's password change mechanism can be utilized without proper
authentication procedures, allowing an attacker to take over the device.
A password change request can be sent directly to the device's HTTP
endpoint without providing valid credentials. The system does not
enforce proper authentication or session validation, allowing the
password change to proceed without verifying the request's legitimacy. |
| Password guessing limits could be bypassed when using LDAP authentication. |
| Pgpool-II provided by PgPool Global Development Group contains an authentication bypass by primary weakness vulnerability. if the vulnerability is exploited, an attacker may be able to log in to the system as an arbitrary user, allowing them to read or tamper with data in the database, and/or disable the database. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. |
| SEL BIOS packages prior to 1.3.49152.117 or 2.6.49152.98 allow a local attacker to bypass password authentication and change password-protected BIOS settings by importing a BIOS settings file with no password set. |
| An unauthenticated user could discover account credentials via a brute-force attack without rate limiting |
| The ISOinsight from Netvision has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access certain system functions. These functions include viewing the administrator list, viewing and editing IP settings, and uploading files. |
| The specific APIs of Parking Management System from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access specific APIs and operate system functions. These functions include opening gates and restarting the system. |
| The web management interface of Okcat Parking Management Platform from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access system functions. These functions include opening gates, viewing license plates and parking records, and restarting the system. |
| A state machine transition flaw in the Bluetooth Low Energy (BLE) stack of Cypress PSoC4 v3.66 allows attackers to bypass the pairing process and authentication via a crafted pairing_failed packet. |