| Hard-coded credentials were included as part of the application binary.
These credentials served as part of the application authentication flow
and communication with the mobile application. An attacker could access
unauthorized information. |
| Certain models of D-Link wireless routers contain an undisclosed factory testing backdoor. Unauthenticated attackers on the local area network can force the device to enable Telnet service by accessing a specific URL and can log in by using the administrator credentials obtained from analyzing the firmware. |
| Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices. |
| CWE-798 Use of Hard-coded Credentials |
| An attacker with local access to the medical office computer can
access restricted functions of the Elefant Service tool by using a
hard-coded "Hotline" password in the Elefant service binary, which is shipped with the software. |
| SSL Pinning Bypass in eWeLink Some hardware products allows local ATTACKER to Decrypt TLS communication and Extract secrets to clone the device via Flash the modified firmware |
| Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0. |
| Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism. |
| A vulnerability classified as critical was found in NuCom NC-WR744G 8.5.5 Build 20200530.307. This vulnerability affects unknown code of the component Console Application. The manipulation of the argument CMCCAdmin/useradmin/CUAdmin leads to hard-coded credentials. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way. |
| Quantum StorNext Web GUI API before 7.2.4 grants access to internal StorNext configuration and unauthorized modification of some software configuration parameters via undocumented user credentials. This affects StorNext RYO before 7.2.4, StorNext Xcellis Workflow Director before 7.2.4, and ActiveScale Cold Storage. |
| UNI-NMS-Lite uses hard-coded credentials that could allow an
unauthenticated attacker to read, manipulate and create entries in the
managed database. |
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. |
| Shenzhen Tuoshi NR500-EA RG500UEAABxCOMSLICv3.4.2731.16.43 devices enable the SSH service by default. There is a hidden hard-coded root account that cannot be disabled in the GUI. |
| Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string. |
| The WorkExaminer Professional server installation comes with an FTP server that is used to receive the client logs on TCP port 12304. An attacker with network access to this port can use weak hardcoded credentials to login to the FTP server and modify or read data, log files and gain remote code execution as NT Authority\SYSTEM on the server by exchanging accessible service binaries in the WorkExaminer installation directory (e.g. "C:\Program File (x86)\Work Examiner Professional Server"). |
| Default credentials were present in the web portal for Airpointer 2.4.107-2, allowing an unauthenticated malicious actor to log in via the web portal |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| An issue was discovered in the G-Net GNET APK 2.6.2. Hardcoded credentials exist in in APK for ports 9091 and 9092. The GNET mobile application contains hardcoded credentials that provide unauthorized access to the dashcam's API endpoints on ports 9091 and 9092. Once the GNET SSID is connected to, the attacker sends a crafted authentication command with TibetList and 000000 to list settings of the dashcam at port 9091. There's a separate set of credentials for port 9092 (stream) that is also exposed in cleartext: admin + tibet. For settings, the required credentials are adim + 000000. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. All dashcams were shipped with the same default credentials of 12345678, which creates an insecure-by-default condition. For users who change their passwords, it's limited to 8 characters. These short passwords can be cracked in 8 hours via low-end commercial cloud resources. |
| Precor touchscreen console P62, P80, and P82 contains a default SSH public key in the authorized_keys file. A remote attacker could use this key to gain root privileges. |