Export limit exceeded: 418312 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (823 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-2405 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-22 | 6.5 Medium |
| CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests. | ||||
| CVE-2026-1227 | 1 Schneider-electric | 2 Ecostruxure Building Operation Webstation, Ecostruxure Building Operation Workstation | 2026-04-17 | N/A |
| CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation. | ||||
| CVE-2026-1226 | 1 Schneider-electric | 2 Ecostruxure Building Operation Webstation, Ecostruxure Building Operation Workstation | 2026-04-17 | N/A |
| CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file. | ||||
| CVE-2026-4832 | 1 Schneider-electric | 25 Easergy P14x, Easergy P24x, Easergy P341 and 22 more | 2026-04-17 | N/A |
| CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port. | ||||
| CVE-2026-1286 | 1 Schneider-electric | 2 Ecostruxure Foxboro Dcs Control Software, Foxboro Dcs | 2026-04-17 | 6.5 Medium |
| CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file. | ||||
| CVE-2026-2273 | 1 Schneider-electric | 1 Ecostruxure Automation Expert | 2026-04-17 | 8.2 High |
| CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file. | ||||
| CVE-2024-8518 | 1 Schneider-electric | 1 Zelio Soft 2 | 2026-04-15 | 3.3 Low |
| CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft 2 application when a specially crafted project file is loaded by an application user. | ||||
| CVE-2024-8530 | 1 Schneider-electric | 1 Data Center Expert | 2026-04-15 | 5.9 Medium |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS. | ||||
| CVE-2024-6918 | 1 Schneider-electric | 1 Accutech Manager | 2026-04-15 | 7.5 High |
| CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. | ||||
| CVE-2025-13905 | 1 Schneider-electric | 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform | 2026-04-15 | N/A |
| CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart. | ||||
| CVE-2025-8453 | 1 Schneider-electric | 2 Saitel Dp, Saitel Dr | 2026-04-15 | 6.7 Medium |
| CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and arbitrary code execution when a privileged engineer user with console access modifies a configuration file used by a root-level daemon to execute custom scripts. | ||||
| CVE-2025-8449 | 1 Schneider-electric | 3 Ecostruxure Building Operation Enterprise Server, Ecostruxure Enterprise Server, Ecostruxure Workstation | 2026-04-15 | N/A |
| CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network. | ||||
| CVE-2025-9996 | 1 Schneider-electric | 1 Blmon | 2026-04-15 | N/A |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session. | ||||
| CVE-2025-9997 | 1 Schneider-electric | 1 Blmon | 2026-04-15 | N/A |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session. | ||||
| CVE-2025-6625 | 1 Schneider-electric | 12 Bmxngd0100, Bmxngd0100 Firmware, Bmxnoc0401 and 9 more | 2026-04-15 | 7.5 High |
| CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device. | ||||
| CVE-2025-7746 | 1 Schneider-electric | 1 Altivar | 2026-04-15 | N/A |
| CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser. | ||||
| CVE-2025-8448 | 1 Schneider-electric | 2 Ecostruxure Building Operation Enterprise Server, Ecostruxure Workstation | 2026-04-15 | N/A |
| CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products. | ||||
| CVE-2024-10498 | 1 Schneider-electric | 1 Powerlogic Hdpm6000 | 2026-04-15 | 6.5 Medium |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality. | ||||
| CVE-2025-54923 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | N/A |
| CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization. | ||||
| CVE-2025-54924 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.5 High |
| CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint. | ||||