| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Internet Explorer in Microsoft Windows 7 SP1, Windows Server 2008 SP2 and R2 SP1, Windows 8.1 and Windows RT 8.1, Windows Server 2012 and R2, Windows 10 Gold, 1511, 1607, 1703, and Windows Server 2016 allows an attacker to trick a user into believing that the user was visiting a legitimate website, due to the way that Internet Explorer handles specific HTML content, aka "Internet Explorer Spoofing Vulnerability". |
| Microsoft Edge in Microsoft Windows 10 Gold, 1511, 1607, 1703, and Windows Server 2016 allows an attacker to trick a user by redirecting the user to a specially crafted website, due to the way that Microsoft Edge parses HTTP content, aka "Microsoft Edge Spoofing Vulnerability". This CVE ID is unique from CVE-2017-8724. |
| SAP NetWeaver AS ABAP 7.40 allows remote authenticated users with certain privileges to cause a denial of service (process crash) via vectors involving disp+work.exe, aka SAP Security Note 2406841. |
| An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| An issue was discovered in SMA Solar Technology products. Sniffed passwords from SMAdata2+ communication can be decrypted very easily. The passwords are "encrypted" using a very simple encryption algorithm. This enables an attacker to find the plaintext passwords and authenticate to the device. NOTE: the vendor reports that only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication. |
| A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to the SiPass integrated server or SiPass integrated client to potentially obtain credentials from the systems. |
| The try_read_command function in memcached.c in memcached before 1.4.39 allows remote attackers to cause a denial of service (segmentation fault) via a request to add/set a key, which makes a comparison between signed and unsigned int and triggers a heap-based buffer over-read. NOTE: this vulnerability exists because of an incomplete fix for CVE-2016-8705. |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system accepts reboot in session from unauthenticated users, supporting a denial of service condition. |
| A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process. |
| AVG AntiVirus for MacOS with scan engine before 4668 might allow remote attackers to bypass malware detection by leveraging failure to scan inside disk image (aka DMG) files. |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations. |
| PwnDoc is a penetration test report generator. In versions up to and including 0.5.3, an authenticated user is able to crash the backend by raising a `UnhandledPromiseRejection` on audits which exits the backend. The user doesn't need to know the audit id, since a bad audit id will also raise the rejection. With the backend being unresponsive, the whole application becomes unusable for all users of the application. As of time of publication, no known patches are available. |
| Product: AndroidVersions: Android kernelAndroid ID: A-212623833References: N/A |
| In registerReceivers of DeviceCapabilityListener.java, there is a possible way to change preferred TTY mode due to a permissions bypass. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-236264289 |
| In strings.xml, there is a possible permission bypass due to a misleading string. This could lead to remote information disclosure of call logs with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-231585645 |
| In ppmpu_set of ppmpu.c, there is a possible information disclosure due to a logic error in the code. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-238939706References: N/A |